random selection: Fe-Se (15 entries found)
Displaying 4 entries out of 4 entries found.
Crystallographic data Sstructural stability [Footnotes] Magnetic properties [Footnotes, magnetic units] Methods References
Materials ID Formula Formula units per cell Atomic sites per cell Crystal system Space group [Number] Formation energy (eV/atom) Energy relative to convex hull (eV/atom) Structure search Averaged magnetic moment (μB/atom) Magnetic polarization, Js (T) Magnetic easy axis Magnetic anisotropy constants:
Ka-c, Kb-c, Kb-a, Kd-a (MJ/m3)
Curie temperature, TC (K) Methods References
MMD-2460 FeNiGe 2 6 hexagonal P6_3/mmc [194] -0.057 . MP 0.51 0.50 c 0.09 . . . . DFT mp-1024972
MMD-2502 FeNiGe 2 6 hexagonal P6_3/mmc [194] -0.147 . MP 0.78 0.75 c 0.51 . . . . DFT mp-1206550
MMD-2628 Fe3Ni3Ge2 3 24 trigonal R3m [160] -0.070 . MP 0.86 0.85 c 0.57 . . . . DFT mp-1225085
MMD-2630 FeNi2Ge 1 4 tetragonal P4/mmm [123] -0.155 . MP 0.60 0.61 c 1.10 . . . . DFT mp-1225094

Footnotes:
  1. Formation energy:
    We perform DFT calculations to calculate the total enegies of all the structures. The formation energy is computed with respect to a linear combination of the total energies of reference elemental phases. When the formation energies are plotted as a function of chemical composition, a set of stable compounds forms a convex hull, which represents a boundary (theoretical lower limit) in a compositional phase diagram. Metastable compounds lie above the hull, and the energy relative to the hull (distance to the hull) is a useful quantity to examine the metastability of a new compound. The lower the formation energy above the convex hull, the more likely it is for the material to exist.
  2. Magnetic anisotropy constants:
    Magnetic anisotropy constant, Ka-c, is defined as Ka-c = Ea-Ec, where Ea and Ec are the total energies per volume for the magnetization oriented along the crystallographic a and c axes, respectively. Similarly, Kb-c and Kb-a are defined as Kb-c = Eb-Ec and Kb-a = Eb-Ea, respectively. For cubic crystal systems, magnetic anisotropy constant is calculated as Kd-a = Ed-Ea, where Ed is the total energy per volume for the magnetization oriented along the body-diagonal direction of the unit cell.

Collaborative PIs:

You can download and use the data of this database for your scientific work, provided that you express proper acknowledgements: